Electronic
Thickness
Gauges
|
Specifically designed for measuring the thickness of any dielectric
material, such as, polymer films, papers, coatings, paint, foam, adhesives, ceramic, rubber, etc.
These gauges are:
- extraordinarily stable
- accurate and precise
- all NON-NUCLEAR
- process capable
- simple to use
- easy to calibrate
- fast and
- affordable
Typical accuracy and resolution from < 0.1 micron to 1.0
micron. *
|
|
| |
Precision Lab stands, custom "C" frames, and automatic Traverses are available for all models.
.
Gauge operating principle
|
|
|
 |
| |
Simply the Best
| |
Electronic Gauges
|
|
5890
|
Digital / Analog laboratory & process thickness gauges.
0.02 to 0.1 micron accuracy * |
|
5850
|
Digital / Analog laboratory & process thickness gauges.
< 0.5 micron accuracy * |
|
5820
|
Digital / Analog laboratory & process thickness gauges. Budget priced!
1.0 micron accuracy )* |
|
5810
|
Digital laboratory & process thickness gauge. Budget priced!
2.5 micron ( 0.0001") accuracy * |
|
| |
Call Today - 704-895-2548
|
| Top |
5890 |
( 0.02 to
0.1 micron accuracy ) |
Electronics / 2mm
Sensor
|
| |
The 5890 thickness gauge is OUR BEST digital, high resolution,
non - contact thickness gauge. With unmatched stability, accuracy, repeatability, and an ultra wide measurement
range; it is the ideal choice for laboratory, quality control, or process applications.
Features:
- Sub - micron accuracy and nanometer resolution
- Large easy to read VFD data display
- Displays 1 part in 100,000
- High speed Digital signal processing
- Ultra high stability
- RS232 data port
- 4 - 20 mA and +/- 10 Volts output
- Auto electronic self zeroing
- Easy calibration via integrated key pad
- Continuous read
- Foot triggering (optional)
- Easy to operate
- Non - nuclear
|
Typical Materials:
- Polyester (PET) film
- Polyethylene film
- Polypropylene film
- Polystyrene film
- Vinyl film
- All other polymer films
- Paper
- Paint
- Rubber
- Ceramic
- Foam
- Adhesives
- Hot Melt films & adhesives
- Fabric
- Thin Foils
|
| |
Technical Data:
| Measurement Range |
0.5, 1, 2, 3, 5, 10
|
mm |
| Sensor Dia. |
8 - 60
|
mm |
| Resolution |
0.004 - .0001 %
|
FSR |
| Linearity |
0.2 %
|
FSR |
| Accuracy 5890 |
< 0.1 µm
|
static measurement 127 µm PET film. |
Accuracy 5890-1
with 1mm sensor |
0.02 µm
|
static measurement 127 µm PET film. |
| Operating Temp. |
10 - 45° C
|
|
| Outputs |
2
|
12 Bit, 4-20 mA, and, 0 to +10 vdc |
| Display |
100,000
|
Counts |
| Display |
0.02, 0.1, 0.5
|
µm |
| Power |
117 vac
|
235 vac optional |
|
|
|
| Top |
5850 |
( 0.5 micron accuracy ) |
Electronics
|
| |
This small, self contained gauge is the perfect choice for
non - contact laboratory and slower speed process applications at a budget price. Built with the same superior
processing of the 5890 model, this gauge also has exceptional accuracy, repeatability, and ease of use.
Features:
- Sub - micron accuracy and nanometer resolution
- Large easy to read VFD data display
- Displays 1 part in 20,000
- High speed Digital signal processing
- Ultra high stability
- RS232 data port
- 4 - 20 mA and +/- 10 Volts output
- Auto electronic self zeroing
- Easy calibration via integrated key pad
- Continuous read
- Foot triggering (optional)
- High speed readings
- Easy to operate
- Non - nuclear
|
Typical Materials:
- Polyester (PET) film
- Polyethylene film
- Polypropylene film
- Polystyrene film
- Vinyl film
- All other polymer films
- Paper
- Paint
- Rubber
- Ceramic
- Foam
- Adhesives
- Hot Melt films & adhesives
- Fabric
- Thin Foils
|
| |
Technical Data:
| Measurement Range |
0.5, 1, 2, 3, 5, 10
|
mm |
| Sensor Dia. |
8 - 60
|
mm |
| Resolution |
< 0.025%
|
FSR |
| Linearity |
1 %
|
FSR |
| Accuracy |
0.5 µm
|
static measurement 127 µm PET film. |
| Operating Temp. |
10 - 45° C
|
|
| Outputs |
2
|
RS232, 4-20 mA, or 0 to +10 vdc |
| Display |
20,000
|
Counts |
| Display |
0.5, 1.0, 2.5
|
µm |
| Power |
117 vac
|
235 vac optional |
|
|
|
| Top |
5820 |
( 1.0 micron accuracy ) |
Electronics
|
| |
The 5820 is a budget priced version of our 5850 gauge. It
is well suited for non - contact laboratory and slower speed process applications. Built with the same digital
processing as our high performance 5890 model, this gauge is AFFORDABLE to anyone who processes films, coatings,
paper, and other web materials. Prices start at
$8,680.00
Features:
- Micron accuracy
- Large easy to read VFD data display
- Displays 1 part in 4,000
- High speed Digital signal processing
- Ultra high stability
- RS232 data port
- Auto electronic self zeroing
- Easy calibration
- Continuous read
- Foot triggering (optional)
- High speed readings
- Easy to operate
- Non - nuclear
|
Typical Materials:
- Polyester (PET) film
- Polyethylene film
- Polypropylene film
- Polystyrene film
- Vinyl film
- All other polymer films
- Paper
- Paint
- Rubber
- Ceramic
- Foam
- Adhesives
- Hot Melt films & adhesives
- Fabric
- Thin Foils
|
| |
Technical Data:
| Measurement Range |
0.5, 1, 2, 3, 5, 10
|
mm |
| Sensor Dia. |
8 - 60
|
mm |
| Resolution |
< 0.05%
|
FSR |
| Linearity |
1 %
|
FSR |
| Frequency |
500 Hz
|
|
| Accuracy |
1.0 µm
|
static measurement 127 µm PET film. |
| Operating Temp. |
10 - 45° C
|
|
| Outputs |
1
|
RS232, Analog optional |
| Display |
4,000
|
Counts |
| Display |
1.0, 2.5
|
µm |
| Power |
117 vac
|
235 vac optional |
|
|
|
| |
5810 |
( 2.5 micron (0.0001") accuracy ) |
Electronics
|
| |
Our NEW 5810 thickness gauge is a low cost solution to your
measurement needs, without sacrificing quality or accuracy.
It has a smaller footprint than our other models and is well suited for non - contact laboratory applications.
This gauge is AFFORDABLE to anyone who processes films, coatings, paper, and other web materials.
Prices start at $5,995.00
Features:
- 2.5 Micron (.0001") accuracy
- Large easy to read LCD data display
- Ultra high stability
- RS232 data port
- Auto electronic self zeroing
- Easy calibration
- Continuous read
- High speed readings
- Easy to operate
- Non - nuclear
|
Typical Materials:
- Polyester (PET) film
- Polyethylene film
- Polypropylene film
- Polystyrene film
- Vinyl film
- All other polymer films
- Paper
- Paint
- Rubber
- Ceramic
- Foam
- Adhesives
- Hot Melt films & adhesives
- Fabric
- Thin Foils
|
| |
Technical Data:
| Measurement Range |
0.5, 1, 2, 3, 5, 10
|
mm |
| Sensor Dia. |
8 - 60
|
mm |
| Resolution |
< 0.05%
|
FSR |
| Linearity |
1 %
|
FSR |
| Frequency |
500 Hz
|
|
| Accuracy |
2.5 µm
|
static
measurement 127 µm PET film. |
| Operating Temp. |
10 - 45° C
|
|
| Outputs |
1
|
RS232, Analog optional |
| Display |
2,000
|
Counts |
| Display |
1.0, 2.5
|
µm |
| Power |
117 vac
|
235 vac optional |
|
| |
* static measurement, 127µm polyester (PET) film. |
|
| Top |
Visit our high performance
Laser
thickness gauges and Optical thickness gauges
for more thickness and displacement measurements.
| - Up to 10 nanometer resolution. |
| - Thick or thin, clear or opaque materials, |
| - Part profiling. |
|